Control Cameras#

Important

Expert function

Control Camera management is an Expert function: it requires knowledge of Cognex VisionPro and C# scripts, and is intended for experienced users. For information on Expert mode, see What it is and When it is needed.

Note

Available from software version v0.24

The functions described in this section were introduced with FlexiVision One v0.24. See the Release Notes – V. 0.24.

In addition to the vision camera used for picking, FlexiVision One manages 3 independent control cameras, associated with FLB1, FLB2 and FLB3 respectively. Control cameras make it possible to perform a visual inspection at the robot’s request, for example to check a picked part, and to return the outcome of the check to the robot.

What it is used for#

The start_control_ command allows the robot to request an inspection from FlexiVision using a control camera. The robot can add a text parameter after the underscore (_): FlexiVision forwards the parameter to the VisionPro script, which decides which tools to run and which results to return.

Important

Operating principle

The HMI configuration remains unchanged: the customer can adapt the inspection rules and the result format by editing their own VisionPro script, without touching the FlexiVision One interface.

Operating sequence#

Actor

Action

1

Robot

Sends start_control_ or start_control_<parameter>.

2

FlexiVision

Acquires the image with the associated control camera and starts the VisionPro script.

3

VisionPro

Runs the selected tools and prepares a text response and a graphic record.

4

FlexiVision

Shows the image and the string in the HMI; sends the string to the robot only if connected.

For each check, FlexiVision manages a Main Task dedicated to the control camera, with error handling, logging and sending of the results to the robot.

Using it from the HMI#

The HMI pages of the control cameras are shared among the devices: select the relevant device from the Control FlexiBowl® section.

Page

Function

Setup Camera Ctrl

Configuration of the control camera.

Setup Tool Ctrl

VisionPro configuration: allows you to work on the tools and on the VisionPro script (see VisionPro Script).

View Runtime

Display of the image and of the check result.

Test Tool

Starts a local check, even without a connected robot.

Note

With the Test Tool command the check is run even without a connected robot: in this case the result is shown in the HMI but is not transmitted via TCP.

Quick acceptance test#

After installing or modifying the VisionPro script, carry out the following checks:

  • ☐ Send start_control_1 and check the text result and the image of PMRedLine 1.

  • ☐ Send start_control_2 and check the text result and the image of PMRedLine 2.

  • ☐ Send start_control_ and check that the string contains both results.

  • ☐ Send start_control_ABC and check the INVALID_CONTROL error of the sample script.

  • ☐ Run Test Tool with the robot disconnected and check that the HMI and VisionPro remain operational.

Further reading#